Homes and commercial establishments have higher power needs. Also, frequent power cuts can hamper the overall performance of the appliances. Luminous Higher KVA offers high quality and reliable power back-up solution for running the office and sensitive equipment. luminous 3.5 kva inverter price
Cruze+ 3.5KVA Inverter with 4 x Luminous Red Charge RC18000 150AH Tall Tubular Battery
Lights, Fans, TV, Music System, Water purifier, PC, Cordless phones, and other small devices luminous 3.5 kva inverter price
Heavy Duty loads
Mixie, Refrigerator, Pump, Induction stove, Air conditioner
Typical Back-Up
Appliances
Night
Day
Even
Light – 40 Watts
6
8
Fan – 60 Watts
6
6
6
TV(32″) / Laptop – 100 Watts
2
2
Desktop PC – 150 Watts
1
2
Battery Back-Up
15.8 hrs
5.1 hrs
4.1 hrs
luminous cruise ranges next-generation technology power backup product it offers a sine wave supply just like the grid power thereby protecting the life of your expensive and sensitive appliances luminous cruise is a perfect now backup solution for your home office and other workplaces life sweet shops showrooms ice cream parlors educational institutions Coaching Institute’s hospital’s retail shops banks restaurants and beauty parlors luminous Cruze range comes in various VA ratings starting from two KVA to 10k VA this flow chart will help you to select the most suitable UPS system for your requirement luminous 3.5 kva inverter price
please note that loads can be run one ate time here we are showing the installation of 3.5 kv a UPS
However the installation procedure will remain the same for all the other UPS in cruise range except for the number of batteries which can be connected to the different PS models depending upon their voltage ratings on the back of this device it has two fans that operates automatically to maintain the temperature of the UPS with this switch user can select between regulated UPS mode and unregulated UPS mode use this battery selection switch to select between tubular plate and flat plate batteries this is battery charging selection the switch position should be selected as for the connected battery capacity[Music]this is a DC MCB our battery MCB this should be turned off before connecting the ups with batteries this is a bypass switch in case of any fault shift this switch manually to bypass mode to bypass the inverter and allow the mains to be available this is a CMC B in case of short-circuit or overload
It will trip to protect your ups and connected loads this is a 4-way input-output terminal block this is used to connect mains input AC supply to the UPS this connector is provided for connecting the unfit of the UPS to load here we are going to use luminous called tubular batteries which carries a capacity of150 ampere ah an output voltage of 12volts as this is a 48 volt UPS we need to connect four 12-volt batteries in series step 1before starting the installation of batteries remember to turn off this battery
MCB since we are installing 150ampere our tubular batteries and sure to set the battery selection switch to tubular and charging switch to medium step 2 can make the first end of this jumper cable to the negative terminal of the first battery and the other end to the positive terminal of the second battery repeat this process to interconnect the other batteries also now join this red wire coming out from the UPS to the positive terminal of the first battery and join the black wire to the negative terminal of the last battery step 3 here on the input terminal there are four different collared wires to take input from the mains and connect the UPS output to the home load green wire should be connected to the earthling light black wire to the neutral line and red wire to the mains light this you know wire is the UPS uncut wire which should be connected to the socket or an MCB box to supply UPS output power to the load this is our main supply put and from output we have connected a diner flyer and now our installation is complete please do not switch on the main supply before switching on the UPS as this may harm the UPS set for now turn on the battery.
MCB and a CNC be at the back of the UPS and switch on the UPS by pressing this button at the front all the indications at the front will glow together for a short duration now switch on the main supply to the UPS now let’s try and understand all indications on the luminous crew’s UPS on displays when UPS is running on battery UPS ON good displays when the UPS trips due to overload in battery mode battery NO display when UPS trips due to low battery this is the mains on indication which tells you the electricity is available to smart charge indicator is on when UPS is charging the batteries battery charging display shows the level of battery charge and now your luminous PS is ready to use so enjoy uninterrupted power with no worries luminous 3.5 kva inverter price